💡 Hot water cylinders work hardest alongside a heat pump — the cylinder stores the heat pump's output for domestic hot water, cutting fossil fuel use to near zero. SEAI grants of up to €1,600 available for hot water cylinders. Apply at seai.ie →
Range · Heat Pump Indirect · Ireland 2026
Range Tribune HE HP 210L — Ireland 2026
High-efficiency heat pump cylinder — the new build default across Ireland
The Range Tribune HE is the most widely specified heat pump cylinder in Irish new builds in 2025–2026, frequently paired with Daikin, Mitsubishi, Samsung and Nibe heat pumps. Its 3.35 m² primary coil is the largest of any copper heat pump cylinder in this directory — delivering the fastest heat transfer at heat pump flow temperatures. The max primary temp of 85°C also accommodates hybrid configurations where a boiler occasionally delivers higher-temperature top-up heating. 25-year warranty on the inner copper cylinder.
210L3.35m² HP coil25-yr warrantyCopperVentedSEAI: part of HP grant
⚙️ Specifications
Capacity
210 litres
Primary (HP) coil area
3.35 m²
Cylinder type
Vented (gravity-fed cold tank)
Inner material
Copper
Insulation thickness
75 mm
Standing heat loss
1.3 kWh/24h
Max primary temp
85°C
Immersion heaters
2 × 3 kW
Dimensions (H × Ø)
1570 × 545 mm
Weight (empty)
50 kg
Warranty
25 years
Made in Ireland
No
💰 Pricing & SEAI grant
Cylinder supply price
~€690
Plus installation labour ~€400–€700 · Total installed ~€1,240
💰 Covered by SEAI Heat Pump System Grant (3 Feb 2026)
The cylinder is included as part of your overall heat pump installation cost. The SEAI grant covers the total installed system cost — heat pump, cylinder, controls, pipework and labour — up to:
① Heat Pump Equipment Grant€6,500
② Central Heating Upgrade (inc. cylinder)€2,000
③ Renewable Heat Bonus (fossil fuel switch)€4,000
Maximum total grant€12,500
Apply at seai.ie — receive Letter of Offer before installation begins. BER assessment required (€200 SEAI grant). Homes built before 2007 need Technical Assessment (€200). Installer must be SEAI-registered.
Key highlights
⚡
3.35 m² coil — fastest heat transfer
The largest primary coil area of any copper cylinder in this directory — meaning the heat pump doesn't have to work as hard to reheat the cylinder, and reheat time is shorter. Direct impact on heat pump COP and running costs
🌡️
85°C max primary temp — hybrid ready
Suitable for hybrid systems where an oil or gas boiler tops up the heat pump in cold weather at higher flow temperatures. Future-proofs the installation
🏗️
New build default in Ireland
Specified in the majority of new A-rated homes built with heat pumps in Ireland in 2025–2026 — proven in Irish water conditions at scale
🏠 Suitable for
New buildRetrofitHeat pumpAll property types
Installation note: Vented cylinders require a cold water storage tank (usually in the loft) feeding by gravity. If your home doesn't have a loft tank, discuss with your plumber whether a vented or unvented cylinder is more appropriate for your installation.
✅ What we like
3.35 m² primary coil — the largest of any copper cylinder in this directory
Max primary temp 85°C — suitable for hybrid heat pump + boiler configurations
210L — right-sized for a typical 3–4 bed Irish home
25-year warranty on inner cylinder
Widely stocked by Irish heat pump and plumbing merchants
Often paired with Nibe S2125 all-in-one system as a matched component
⚠️ Worth knowing
Not manufactured in Ireland — manufactured in UK
Copper inner — subject to hard water corrosion over time in high-hardness areas
75mm insulation — slightly thinner than some competitors at 80mm
🌡️ Compatible heat pump brands
The Tribune HE HP 210L is compatible with all major air-to-water heat pump brands and is factory-recommended or shipped with Nibe S2125. See the Heat Pump Directory for full specifications, pricing and SEAI grant details on all 19 heat pumps available in Ireland.
The Range Tribune HE HP 210L cylinder itself costs approximately ~€690. Installation (remove existing cylinder, connect to heat pump primary circuit, commission immersion backup) adds approximately €400–€700. Total installed cost: typically ~€1,240. This is usually included in the overall heat pump installation quote from your SEAI-registered installer — ask for the cylinder to be itemised on the quote so you can compare against other brands.
In most cases, no — your existing cylinder should be replaced as part of the heat pump installation. Standard cylinders have small primary coils (1.5–2.0 m²) designed for boiler temperatures of 70–80°C. Heat pumps deliver water at 45–55°C and need a much larger coil (typically 2.8–3.4 m²) to transfer adequate heat at the lower temperature. The Range Tribune HE HP 210L has a 3.35 m² primary coil — specifically sized for heat pump low-temperature operation. Using a standard cylinder with a heat pump results in slow reheat, inefficient operation, and higher running costs.
Yes — the cylinder cost is included within the SEAI Heat Pump System Grant (up to €12,500 for houses switching from fossil fuel heating, from 3 February 2026). The grant is applied to the total installed system cost including heat pump, cylinder, controls, pipework and labour — not as a separate per-component payment. Cylinders are not individually grant-funded as standalone items. A BER assessment is required before the grant can be drawn down, and all work must be carried out by a SEAI-registered contractor. The Range Tribune HE HP 210L's ~€690 cylinder cost contributes toward the Central Heating Upgrade element of the grant (up to €2,000).
A heat pump cylinder is typically set to 55–60°C to balance legionella risk with heat pump efficiency. Legionella bacteria cannot survive above 60°C. Most heat pump systems include a weekly legionella protection cycle where the immersion heater in the Range Tribune HE HP 210L raises the full cylinder to 60–70°C. Day-to-day, the heat pump heats the cylinder to the setpoint temperature (often 50–55°C) — a heat pump's COP drops significantly above 55°C. The Range Tribune HE HP 210L's max primary temperature of 85°C accommodates both routine heat pump operation and legionella protection cycles. Your installer will configure the legionella cycle as part of commissioning.
The Range Tribune HE HP 210L at 210L is suited to a typical 3–4 bedroom family home. A heat pump heats the cylinder slowly over 2–4 hours (compared to a boiler's rapid reheat) — so the system is usually programmed to heat the cylinder once or twice daily, storing enough hot water for the day's demand. General guideline: allow 40–50 litres per person per day. For a 4-person household with a heat pump: 160–200L minimum. Homes with high shower use or a bath should consider 200–250L.
Copper is the most widely used material for hot water cylinders in Ireland and works perfectly well in most locations. The Range Tribune HE HP 210L's copper inner is fully compatible with heat pump operation at 45–60°C. Copper becomes less ideal in two situations: hard water areas (Dublin, Kildare, Meath — calcium deposits accelerate internal corrosion over 15–20 years) and coastal properties within 5–10km of the sea (salt air degrades exposed copper fittings). For soft water areas and inland properties, copper is the most cost-effective choice. For hard water or coastal areas, consider the Kingspan Albion Ultrasteel (duplex stainless) or Telford Tempest (stainless 304) instead.
Heat transfer through a coil depends on temperature difference (ΔT), flow rate, and coil surface area. In a boiler system, ΔT is large (boiler at 75°C, cylinder at 55°C → ΔT = 20°C) — even a small coil transfers heat quickly. In a heat pump system, ΔT is small (HP at 50°C, cylinder at 45°C → ΔT = 5°C). With a small ΔT, you need a much larger coil surface area to transfer the same heat. The Range Tribune HE HP 210L's 3.35 m² primary coil — one of the largest available — compensates for the low temperature differential, allowing the heat pump to operate at lower, more efficient flow temperatures without sacrificing reheat time. Standard boiler cylinders typically have only 1.5–2.0 m² coils — using one with a heat pump results in slow reheat and the heat pump working harder and less efficiently.
Heat transfer through a coil depends on three factors: temperature difference (ΔT), water flow rate, and coil surface area. In a boiler system, ΔT is large (boiler water at 75°C, cylinder water at 55°C → ΔT = 20°C) so even a small coil transfers heat efficiently. In a heat pump system, ΔT is small (HP water at 50°C, cylinder water at 45°C → ΔT = 5°C). With a small ΔT, you need a much larger coil surface area to transfer the same amount of heat. The Tribune HE's 3.35 m² coil compensates for the low temperature differential by providing more surface contact — letting the heat pump run at lower, more efficient flow temperatures without sacrificing reheat time.
Yes — the Tribune HE is a universal heat pump indirect cylinder compatible with all air-to-water heat pump brands including Daikin Altherma, Mitsubishi Ecodan, Samsung EHS, Vaillant aroTHERM, Grant Aerona4, Nibe S-series, Panasonic Aquarea, Worcester Bosch Greenstar and others. Some heat pump brands (Daikin, Nibe) include a matched cylinder in the package — always check whether your heat pump quote includes the cylinder or requires it separately.
Get it installed
Find SEAI-registered heat pump installers for the Range Tribune HE HP 210L
Your installer will supply and install both the heat pump and the Range cylinder as a complete SEAI-eligible system. Tell us what combination you need — we match you with up to 3 SEAI-registered installers in your area. Free and no obligation.
💧 Get heat pump + cylinder quotes
Up to 3 SEAI-registered installers in your area will contact you within 1 business day with system recommendations and pricing — including the Range Tribune HE HP 210L cylinder.
💶 Get quotes
3 local installers · 1 business day
💬 Get advice first
Free assessment · no obligation
Your details are only shared with SEAI-registered Irish heat pump installers. No spam — ever.
✅
Request sent!
We're matching you with up to 3 SEAI-registered heat pump installers in your area who supply the Range cylinder. Expect contact within 1 business day.
De Energy Hub
More power to youTM.
🌾 Built for farms, agri businesses & rural operators
Your renewable installation is also a charging asset — list it
Agricultural businesses installing heat pumps and solar can immediately list their EV charger as a Pure Energy Charging Hub — powered by your own generation. Rural EV charging infrastructure is in high demand. Self and guest bookings available — book charging sessions for contractors and visitors before they arrive.
☀️ Pure Energy🔄 Smart Energy🚀 Boost Energy
☀️
Pure Energy from your system
Tag your charger as Pure Energy — drivers see it runs on 100% renewable generation from your farm
🤝
Guest & self-booking
Book sessions for contractors or visitors who don't have the app — they're notified and guided through check-in
📸
Photo check-in
Customers upload a photo on check-in or check-out — added accountability for shared rural infrastructure
The Range Tribune HE HP 210L is designed to work with the following heat pumps, solar diverters and smart energy products from our Irish directories. It is supplied as standard with Nibe S2125 installations.
Solar diverters — use surplus solar for free hot water
This cylinder has an immersion heater — which means it can receive free hot water from surplus solar. A solar diverter intercepts solar surplus before it exports to the grid and redirects it straight to your immersion, typically providing 60–80% of annual hot water from the sun. Payback is usually under 18 months.
A 4kWp solar system generates approximately 3,600 kWh/year in Ireland. With a solar diverter redirecting surplus to this cylinder's immersion heater, you can cover 60–80% of annual hot water energy for free — on top of the heat pump doing the heavy lifting.
EV charger + home battery — run everything on solar
Your heat pump and this cylinder provide low-carbon heating and hot water. Add solar panels, a home battery and an EV charger and you can power your car, your heating and your hot water from the same roof — the combined SEAI grants available reach up to €14,600.
A hot water cylinder upgrade is often the first step in a wider home energy transformation. With a solar diverter filling your cylinder for free during the day, the next natural step is an EV — charged overnight on cheap night-rate electricity or from surplus solar. See all 205+ EVs in the EV Vehicle Directory.
💧 Solar hot water + EV: your whole home running on free energy
☀️ Solar diverter
Free hot water
surplus solar → cylinder
🚗 Smart EV charger
Free driving
surplus solar → your EV
💶 Combined saving
~€3,000/yr
hot water + fuel combined
A myenergi Eddi fills your cylinder with free solar. A myenergi Zappi in Eco+ mode fills your EV with whatever solar is left — both share generation data via the Hub so they never compete. View myenergi Eddi →